Manual 0-5304 MAINTENANCE 5-1
SECTION 5: MAINTENANCE
5.01 General Maintenance
Perform the following checks periodically to ensure proper system performance.
Power Supply Maintenance Schedule
Daily
Check coolant level; add coolant as needed.
Check gas hose connections and pressures.
Check cooling fan; clean as needed.
Weekly
Check O-Rings in Torch and Cartridge
Monthly
Check cooling fan and radiator; clean as needed.
Check gas hoses for cracks, leaks, or abrasion.
Replace as needed.
Check all electrical connections for cracks or
abrasion. Replace as needed.
Clean water lter (if using H
2
O Mist)
Six Months
Clean or replace coolant lter.
Clean coolant tank.
Vacuum out any dust buildup inside power supply.
5.02 External Coolant Filter Cleaning Procedure
Periodic cleaning of the coolant filter ensures maximum coolant flow efficiency. Poor coolant flow causes inefficient torch
parts cooling with consequent faster consumable wear.
Clean the coolant filter as follows:
1. Disconnect system from main input power.
2. Unscrew and remove the filter canister by hand. Large canister located at the back of the power supply. Be sure to
keep the O-ring.
3. Inspect and replace filter as needed. Re-install the canister, tightening it by hand. Be sure the O-ring is in place.
4. Turn the system on and check for leaks.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Thermal Dynamics ULTRA-CUT 200 XT™ and is the answer not in the manual?

Thermal Dynamics ULTRA-CUT 200 XT™ Specifications

General IconGeneral
BrandThermal Dynamics
ModelULTRA-CUT 200 XT™
CategoryWelding System
LanguageEnglish

Related product manuals