10 Commissioning
10.1 Installer access
Certain functions will be locked and only accessible with the correct access code. To gain access, the following steps must be made:
1. Press on the Start screen to open the Menu screen.
2.
Press
3. Press the input area to open up the num pad.
4. Enter the code for installer access, 607080 and confirm by pressing the white tic in the lower right corner.
5. Once back in the previous menu, the green tic in the lower right corner needs to be pressed, to make the final confirmation.
Note:
▪
The access code is active for 8 hours. After 8 hours, logging out or restart, the code must be entered again.
10.2
Online
The heat pump is factory prepared for monitoring remotely via internet. (Thermia Online)
In order to use the Thermia Online service:
▪
Make sure that there is an available internet connection (router or equivalent) in the building
▪
Connect the commissioned heat pump to an existing internet connection (router or equivalent). Use the RJ45 connection placed
below the display (CM module) behind the front panel. Use a patch cable (not cross over cable).
▪
1. Press
on the Start screen to open the Menu screen.
2.
Press on Settings .
3. Press on the text System settings.
4. Press on the text Online.
5. Press
to activate.
▪
Make a note of the heat pump MAC-address. The MAC-address is also available in the Network menu in the display
▪
An account and registration is required to use the Thermia Online service.
For more information, see:
www.thermia.com/online
10.3
Alarms
During commissioning and start up, alarms sometimes may appear. Press to get more information about the alarm when it has
occurred. Press
visible in the alarm log. (A more detailed technical information will appear for the logged in installer compared to
the end customer).
Installation Guide
Athena
Thermia AB AWAT01IGCG0102
47