EasyManua.ls Logo

Thermo King CSR Series - Gauge Manifold Valve Positions; Figure 41:Balancing the Pressure; Figure 42:Removing Refrigerant; Figure 43:Gauge Manifold Closed to Center Port

Thermo King CSR Series
189 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Refrigeration Maintenance and Service Operations
133
Gauge Manifold Valve Positions
The gauges indicate low and high side pressures.
Operate one or both hand valves to perform the
different service operations.
1. Quick Disconnect Access Valve
2. Discharge Service Valve (DSV)
3. Suction Service Valve (SSV)
Figure 41: Balancing the Pressure
1. Quick Disconnect Access Valve
2. Discharge Service Valve (DSV)
3. Suction Service Valve (SSV)
4. Reclaimer
5. In
6. Out
Figure 42: Removing Refrigerant
AXA0241
AXA0242
1. Close Hand Valves
Figure 43: Gauge Manifold Closed to Center Port
1. Open Hand Valves
Figure 44: Gauge Manifold Open to Center Port
1. Quick Disconnect Access Valve
2. Discharge Service Valve (DSV)
3. Suction Service Valve (SSV)
Figure 45: Charging the System
AXA0181
AXA0182
AXA0243

Table of Contents

Related product manuals