MP-3000 Controller
80
1. Press the F1 key to enter the Main menu.
2. Press F2 key to scroll through Main menu
until “COMMANDS” appears in LCD
display.
3. Press F4 key to access the Commands menu.
The first command in the submenu appears in
the LCD display.
4. Press F2 or F3 key to scroll to the desired
command:
•“PTI” (Pre-trip) TEST”
•“POWER MANAGEMENT”
•“FUNCTION TEST”
•“MANUAL FUNCTION TEST”
5. Press F4 key to activate the command
selected.
•“PTI (Pre-trip) TEST”: LCD display
shows PTI Test currently being
performed. PTI test ends automatically.
Press any key on the controller to return
the unit to normal operation.
•“POWER MANAGEMENT”: LCD
display shows current Power Limit setting
and Power Time setting. Turn Power
Limit feature on and off, change power
limit setting or change power limit time.
•“FUNCTION TEST”: LCD display shows
functional test currently being performed.
Function test ends automatically. Unit
automatically returns to normal operation.
•“MANUAL FUNCTION TEST”: LCD
display shows list of unit components.
Test the operation of individual
components or turn several components on
at the same time to perform a system test.