4 Programming (SDK)
305
hCam
Camera handle
image); the following rule applies independently of the
image bit depth:
0 = black
128 = 50% gray (default)
255 = white
Note on the sensor's internal control functionality
When using the sensor's internal control functionality, you
can only used values in a range between [44...235]. The
increment in this range is 4. Smaller values are
automatically set to 44, larger values to 235.
IS_GET_AUTO_REFERENCE
Returns the set point for auto gain control/auto exposure
shutter.
Control parameters
pval1: returns the current setting
IS_SET_AUTO_GAIN_MAX
Sets the upper limit for auto gain control.
Control parameters
pval1: valid value for gain (0...100)
IS_GET_AUTO_GAIN_MAX
Returns the upper limit for auto gain control.
Control parameters
pval1: returns the current setting
IS_SET_AUTO_SHUTTER_MAX
Sets the upper limit for auto exposure shutter.
Control parameters
pval1: valid exposure value (0 sets the value
continuously to max. exposure)
IS_GET_AUTO_SHUTTER_MAX
Returns the upper limit for auto exposure shutter.
Control parameters
pval1: returns the current setting
IS_SET_AUTO_BRIGHTNESS_ONCE
Enables/disables the automatic disable for automatic
brightness control (gain and exposure time)
*2
Control parameters
pval1 = 1 enables control, 0 disables control
IS_GET_AUTO_BRIGHTNESS_ONCE
Returns the automatic disable status
*2
Control parameters
pval1: returns the current setting
Speed and hysteresis
IS_SET_AUTO_SPEED
Sets the speed value for the auto function.
Control parameters
pval1: defines the control speed (0...100)
IS_GET_AUTO_SPEED
Returns the speed value for the auto function.
Control parameters
pval1: returns the current setting
IS_SET_AUTO_SKIPFRAMES
Sets the number of frames to be skipped during
automatic control.
Control parameters
pval1: defines the number of frames to be skipped
during automatic control (default: 4)
IS_GET_AUTO_SKIPFRAMES
Returns the number of frames to be skipped during
automatic control.
Control parameters
pval1: returns the current setting
IS_GET_AUTO_SKIPFRAMES_RANGE
Returns the permissible range for the number of frames
to be skipped.

Table of Contents

Other manuals for THORLABS DCU22 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the THORLABS DCU22 Series and is the answer not in the manual?

THORLABS DCU22 Series Specifications

General IconGeneral
BrandTHORLABS
ModelDCU22 Series
CategorySecurity Camera
LanguageEnglish

Related product manuals