4 Programming (SDK)
307
hCam
Camera handle
Control parameters
pval1: defines the red level offset (-50...50)
pval2: defines the blue level offset (-50...50)
IS_GET_AUTO_WB_OFFSET
Returns the offset values for the red and blue channels.
Control parameters
pval1: returns the red level offset (-50...50)
pval2: returns the blue level offset (-50...50)
IS_SET_AUTO_WB_GAIN_RANGE
Sets the color gain limits for auto white balance.
Control parameters
pval1: sets the lowest gain value
pval2: sets the highest gain value
IS_GET_AUTO_WB_GAIN_RANGE
Returns the color gain limits for auto white balance.
Control parameters
pval1: returns the minimum permitted gain value
pval2: returns the maximum permitted gain value
IS_SET_AUTO_WB_ONCE
Sets automatic disabling of auto white balance
*2
Control parameters
pval1 = 1 enables control, 0 disables control
IS_GET_AUTO_WB_ONCE
Returns the automatic disable status
*2
Control parameters
pval1: returns the current setting
Speed and hysteresis
IS_SET_AUTO_WB_SPEED
Sets the speed for auto white balance.
Control parameters
pval1: defines the control speed (0...100)
IS_GET_AUTO_WB_SPEED
Returns the speed for auto white balance.
Control parameters
pval1: returns the current setting
IS_SET_AUTO_WB_HYSTERESIS
Sets the hysteresis value for auto white balance.
Control parameters
pval1: defines the hysteresis value (default: 2)
IS_GET_AUTO_WB_HYSTERESIS
Returns the hysteresis value for auto white balance.
Control parameters
pval1: returns the current setting
IS_GET_AUTO_WB_HYSTERESIS_RANGE
Returns the permissible range for the hysteresis value.
Control parameters
pval1: returns the minimum permitted value
pval2: returns the maximum permitted value
IS_SET_AUTO_WB_SKIPFRAMES
Sets the number of frames to be skipped during
automatic control.
Control parameters
pval1: defines the number (default: 4)
IS_GET_AUTO_WB_SKIPFRAMES
Returns the number of frames to be skipped during
automatic control.
Control parameters
pval1: returns the current setting
IS_GET_AUTO_WB_SKIPFRAMES_RANGE
Returns the permissible range for the number of frames
to be skipped.
Control parameters

Table of Contents

Other manuals for THORLABS DCU22 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the THORLABS DCU22 Series and is the answer not in the manual?

THORLABS DCU22 Series Specifications

General IconGeneral
BrandTHORLABS
ModelDCU22 Series
CategorySecurity Camera
LanguageEnglish

Related product manuals