TMQ AP4 Autopilot (AP4S10) 10 of 62 Version 4.96 9/10/2017
To reset timer when alarm sounds
When set time expires an alarm will sound
Press TIMER button
Time is reset to original time
Note: If an external alarm is fitted, this will sound 1 minute after the internal
alarm if the timer has not been reset or muted.
To disable (mute) watch timer
Press TIMER button
Rotate COURSE knob until display reads 000
Press TIMER button again
Commercial Boat Watch Timer
Used where survey regulations for commercial vessels require a watch timer
(which includes an external alarm) fitted with an autopilot.
Note:
Once the commercial watch alarm has been enabled, it cannot be
disabled by the user.
To enable the commercial watch timer alarm
Switch AP4 to SET mode.
Hold down the GPS button and press TIMER button
Display shows [900]
Rotate COURSE knob until display reads [906]
Press the TIMER button again
Display shows [A-0]
Rotate COURSE knob until display reads [A-1]
Press the TIMER button
Display shows [A00]
Dial up Commercial Regulation Time, eg: for QLD dial [A05]
Press TIMER button again
Display then reverts to normal heading.