TMQ AP4 Autopilot (AP4S10) 24 of 62 Version 4.96 9/10/2017
Installation of the magnetic Compasses
There are two other types of compass which may be supplied for this autopilot.
A compass-top sensor (TMQ CTS), or a magnetic sensor unit (TMQ fluxgate
compass - COMMAG),
Wiring
The magnetic sensor unit or compass-top-sensor, which is supplied with your
AP4 autopilot, is fitted with a plug, which fits into the COMPASS socket on the
rear of the autopilot. If the cable must be extended, we recommend that TMQ 5-
core shielded extension cable be used. This is available from your supplier or
TMQ Electronics.
Installing a Compass-Top Sensor (CTS)
A compass top sensor should be used as the heading reference unit for steel
boats. Before attaching the CTS to the top of a flat top compass, ensure there
are no defects in the compass, eg: sticking card, as this will affect the operation
of the autopilot.
Position
Firstly determine the correct position of the CTS on the compass glass
top (CTS is central and cable facing aft)
Route the cable to the AP4 control unit position
Plug cable into AP4 compass socket
Before fixing the CTS to the compass surface, switch on the AP4, align
the CTS carefully so that the AP4 display reads the same as the boat
magnetic compass
When position is correct attach the CTS with double sided tape