EasyManua.ls Logo

TMQ AP4 - Troubleshooting

TMQ AP4
62 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TMQ AP4 Autopilot (AP4S10) 60 of 62 Version 4.96 9/10/2017
Troubleshooting
Note: Before carrying out any trouble shooting procedures, ensure your test
equipment is working correctly!!
AP4 does not switch on:
Possible fault
No power available at AP4
Defective power cable connection
Faulty Mode switch on AP4
Component failure in AP4 power regulator circuit
AP4 switches on but no drive output
Possible fault
No compass input
Defective drive cable connections
Failure of drive switching circuit in AP4 (FET’s)
Defective MODE switch in AP4
FUS Displayed open Fuse Internal 15A Blade Fuse
AP4 working but rudder does not move
Possible fault
Defective drive connection cable
Worn drive motor brushes
Drive motor failure
Pump failure (hydraulic drive)
Air in hydraulic lines
Ram connection on tiller
Broken drive chain or cable (mechanical drive)
FUS Displayed open Fuse Internal 15A Blade Fuse