34. Programming Table
Number of
“Override”
presses
Confirma-
tion
Description of function
1
CHIRP
1
CHIRPS
1
CHIRPS
1
CHIRPS
1 short “CHIRP” Time to stop engine after remote start (min) 5 10 15 20
2 times
2 short “
CHIRPS”
Specified engine temperature for automatic warm-up (
-5 -10 -20 -30
3 times
3 short “
CHIRPS”
Starter operation time for remote start-up (msec) 800 1200 1800 3000
Engine operation control on order: Ver.1 Ver.2 Ver.3
5 times
1 long “CHIRP” Time for enabling 2-nd auxiliary channel (sec) 0.8 10 30 constant
1L+1S “
CHIRPS”
Siren impulse duration (msec) 100 10 15 20
7 times
1L+2S “
CHIRPS”
Cable IGN 2 (ON/OFF) / Door closing at remote start-up Ver.1 Ver.2 Ver.3 Ver.4
8 times
1L+3S “
CHIRPS”
Starter ON delay before gasoline/diesel engine start (sec) 2 10 10 10
9 times
1L+4S “
CHIRPS”
Duration of central lock opening/closing impulse (sec) Ver.1 Ver.2 Ver.3 Ver.4
10 times
2 long “
CHIRPS”
Two-step door opening or 3rd auxiliary
channel/immobilizer
Ver.1 Ver.2 Ver.3 Ver.4
2L+1S “
CHIRPS”
Safe driving function OFF Ver.1 Ver.2 Ver.3
12 times
Auto arming Ver.1 Ver.2 Ver.3
13 times
Cabin lighting delay count (sec) 1 15 30 45
Time for cabin light switch ON/window raising (sec) Ver.1 Ver.2 Ver.3 Ver.4
15 times
3 long “
CHIRPS”
Temperature measurement units/type of locking (black
and white cable)
Ver.1 Ver.2 Ver.3 Ver.4
16 times
3L+1S “
CHIRPS”
Turbo- timer OFF 1 min 3 min 6 min
NOTE:
The system confirms selected functions using siren “
CHIRPS”
: L – long “
CHIRP”
, S – short “
CHIRP”
.
Function is confirmed using the following siren “
CHIRPS”
:
– 1 “
CHIRP”
, – 2 “
CHIRPS”
, – 3 “CHIRPS”, – 4 “
CHIRPS”
ATTENTION!
Factory settings for programmable functions are underlined.
19