48 TMR4610 Operators Manual D4208-EN
SETTING
[display]
D.A.N.
NO.
OPTIONS [displayed]
BOLD=DEFAULT
DESCRIPTION
AUTO PRINT
(APRINT)
2303
ON/OFF
If ON -pressing keys auto-
prints weight values.
PRINT FORMAT
(PRTFMT)
2304
AUTO, WTONLY, DOWNLD,
DT+TM, ID+TM, IDWTTM,
BATCH1, PRTAC1, PRTAC2,
PRTAC3, PRWTRC,
WTRCTM,3200-A, 3200-B,
SCLABC,32-TMR, FDINFO,
FEED-1
Select alternate & comma
(CSV) formats.
PRINT
ACCUMULATION
(PRTACC)
2305
0
Shows a running total of
weights printed.
REMOTE DISPLAY
(RMDISP)
2401
EZ2, EZ3MUX, COG, NONE
Select type of remote display
REMOTE TERMINAL
(RMTERM)
2402
ON/OFF
Sends display data to serial
remote terminal interface
BAR GRAPH MODE
(BARGRP)
2411
OFF, RIGHT, LEFT, MIDOUT, MID
IN.
Selects output for a bar graph
display when used with an
RD4000 Remote Display
WEIGHT GRAPH
(WTGRPH)
2412
ON/OFF
Enables graph to be used
with weight when used with a
RD4000 Remote Display.
BAR WEIGHT
(BAR WT)
2413
12000
Enter the full scale gross
weight for the bar graph
display.
PRESET GRAPH
(PRGRPH)
2414
ON/OFF
Enables graph to be used
with presets when used with
an RD4000 Remote Display.
TIMER GRAPH
(TMGRPH)
2415
ON/OFF
Enables graph to be used
with timers when used with
an RD4000 Remote Display.
MENU 3 - MOTION & WEIGHT
DISPLAY COUNT
(COUNT)
3001
.01,.02,.05,.1,.2,.5,1,2,5,10,20,
50,100
Select display count size of
weigh values.
CAPACITY
(CAP)
3002
40,000
Enter MAXIMUM weight
measurable on scale.
WM1 ADJUST 1
(WMA1-1)
3003
10
Increase this number to
smoothing weighing
WM1 ADJUST 2
(WMA1-2)
3004
4
0=off. Use value less than
WMA1-1 for quick response
weight.