265
35. SPECIFICATIONS
*4: Figures when using Kodak Gray Card White side (reflection factor 90%)
and brightness level is less than 30000 lx (a little cloudy).
*5: Figures when using Kodak Gray Card Gray side (reflection factor 18%)
and brightness level is less than 30000 lx (a little cloudy).
*4,*5: When performing reflectorless measurement, the possible measurement
range and precision will change depending on the target reflection factor,
weather conditions and location conditions.
*6: Face the prism toward the instrument during the measurement with the
distance at 10 m or less.
*7: At the time of the tracking measurement.
Internal memory
Capacity 5,000 measurement points
Data transfer
Data input/output Asynchronous serial, RS232C compatible
Power Supply
Power source: Rechargeable Li-ion battery BDC46C
Working duration at 20 °C:
Distance and angle measurement
(Fine single measurement = every 30 sec.) :
BDC46C: about 15 hours
Battery state indicator: 4 levels
Auto power-off: 5 levels (5/10/15/30 min/Not set) (selectable)
Charging time at 25 °C: about 2.5 hours (using CDC68A)
*8
Battery (BDC46C)
Nominal voltage 7.2V
Capacity 2430mAh
Dimensions 38 (W) x 70 (D) x 20 (H) mm
Weight about 103g
Charger (CDC68A)
Input voltage: AC100 to 240V
Charging time per battery (at 25°C):
BDC46C: about 2.5 hours
(Charging can take longer than the times stated
above when temperatures are either especially
high or low.)
Charging temperature range:
0 to 40°C
Storage temperature range:
-20 to 65°C