Page #21 background imageLoading...
Page #21 background image
21
FCM II Installation Guide: 20160419 - Part # 2307
3.2.3 ADDITIVE WIRING
Note: Most additive injection meters only provide an Open-Collector (pull down) type output. Typically a 1,000
Ohm, ¼ watt pull-up resistor needs to be added in the pulser junction box to pull this output to 12V+ when the
output is off.
Line
#3 Additive
Valve
Solenoid
#4 Additive
Valve
Solenoid
Neutral
12V+
Gnd
#1 Additive
Valve
Solenoid
#2 Additive
Valve
Solenoid
#1 Additive
Meter Pulser
or Switch
#2 Additive
Meter Pulser
or Switch
#3 Additive
Meter Pulser
or Switch
#4 Additive
Meter Pulser
or Switch
Port 0 Output
Port 1 Output
Port 3 Output
Port 2 Output
Port 7 Input
Port 6 Input
Port 5 Input
Port 4 Input
12V+
Gnd
- - + +
D4 D3 D2 D1
12Vdc
Top Side
Bottom Row
In Out In Out
B1 B2 B3 B4
Bottom Side
Middle Row
Port 3
Port 2
A
B
E
D
F
Terminal
Number
- + - +
E4 E3 E2 E1
Top Side
Middle Row
Port 5
Port 4
- + - +
F4 F3 F2 F1
Top Side
Top Row
Port 7
Port 6
In Out In Out
A1 A2 A3 A4
Bottom Side
Bottom Row
Port 0
Port 1
1234
1 2 3 4
Figure 3.4 FCM II Field Wiring: Additive Meters and Injection Valves