rangeofthenozzlesorthereisaproblemwiththe
spraysystem.
CleaningtheSprayer
Important:Youmustalwaysemptyandcleanthe
sprayerimmediatelyaftereachuse.Failuretodo
somaycausethechemicalstodryorthickeninthe
lines,cloggingthepumpandothercomponents.
Cleanthespraysystemaftereachsprayingsession.To
properlycleanthespraysystem:
•Usethreeseparaterinses.
•Useaminimumof50gallonsforeachrinse.
•Usethecleanersandneutralizersasrecommended
bythechemicalmanufacturers.
•Usepurecleanwater(nocleanersorneutralizers)
forthelastrinse.
Therinsetankislocatedatthefront,rightsideofthe
chemicaltank(Figure25).Ifyouinstalltheoptional
RinseKit,youcanllthistankwithfreshwaterand
automaticallyrinsethemaintank,boomsupplylines
andnozzles.
Figure25
1.Rinsetank(forusewiththeoptionalrinsekit,106-4842)
1.Stopthesprayer,settheparkingbrake,placethe
rangeselectorintheNeutralposition,andturnoff
theengine.Thetankwilldraintoleftsideofthe
machine.
2.Locatethetankdrainvalveontheleftsideofthe
machine(Figure26).Thevalveisontheframein
frontofthefueltank.
Figure26
1.Tankdrainhandle
Openthevalvetodrainanyunusedmaterial
fromthetankanddisposeofitaccordingtolocal
codesandthematerialmanufacturer’sinstructions
(Figure27).Afterdraining,removethelynchpinon
thebracketsecuringthedrainvalvetothemachine
andletthevalverestontheground.Thisallows
anyresidualmaterialinthelinetodrain.
Figure27
1.Valveopen3.Valveclosed
2.Lynchpin