4.Installandtightenthedrainplugwhentheuid
stopsdraining.
5.Addapproximately1quart(1L)ofMobilSHC634
SyntheticLubricanttothelltube.
Important:UseonlyMobilSHC634Synthetic
Lubricantorequivalentsyntheticuidinthe
gearbox.Non-syntheticoilsmaybreakdown
causingdamagetothepumpgearbox.
6.Installthellplug.
Cleaning
CleaningtheFlowmeter
ServiceInterval:Every400hours/Yearly(whichever
comesrst)
Occasionally,theowmetermayneedtobecleanedto
removeanobstruction.
Note:Makesurethepumpisoffwhenperforming
thisprocedure.
1.Disconnecttheowmeterwirefromwiringharness.
2.Removetheretainingcapfromtheowmeterbody
(Figure70).
Figure70
1.Retainingcap3.Flowmeterbody
2.Paddlewheelassembly
3.Carefullypullthepaddlewheelassemblyfromthe
body.
4.Usewarmwater,asoft-bristledbrush,andamild
detergentasnecessarytocleantheowmeterbody
andpaddlewheel.Removeanysmallmetallicdebris.
Important:Donotusesolventsorfueltoclean
theowmeter.
5.Installthepaddlewheelassemblyintotheowmeter
body.
Important:Thepaddlewheelassemblywill
onlytintothebodyoneway,inadetentsloton
thesideofthebody.Donotforcethepaddle
55