CalibratingtheSprayPro
Monitor
Figure28
1.LCDscreen
6.Applicationrate11.Reset,calibrationbutton
16.Selectunits
2.Selectiondial7.SubArea12.Calibrate,calibrationbutton
17.Width
3.Totalarea8.Distance13.Decrease,calibrationbutton
18.Speedcalibration
4.Speed9.Subvolume
14.Increase,calibrationbutton19.Flowmetercalibration
5.Unitsofmeasure
10.Totalvolume15.Boomselection20.LED
TheSprayPromonitorhasacalibrationmodethat
allowsyoutochangevarioussettingstocustomizethe
displayandcalibratethemonitortoyourneeds.You
cancalibrateorchangethefollowingsettings:
BoomWidth
UnitsofMeasure
Speed
Flowmeter
SettingtheBoomWidth
Thedefaultsettingsfortheboomwidthsare80inches
(2.03m)fortherightandleftboomsand60(1.524m)
forthecenterboom.Thisisbasedon4nozzleson
therightandleftboomsand3onthecenterboomall
spaced20inches(50.8cm)apart.Ifyouchangethe
spacingofthenozzles,youshouldchangetheboom
widthtoreectyourchangesasfollows:
1.Stopthesprayerandsettheparkingbrake.
2.SetthemasterboomswitchtotheOffposition.
Themonitordisplays“HOLD”.
3.PressandholdtheCalibratebuttonuntilthe
monitordisplays“CALHOLD”andtheredlight
onthemonitorilluminates.
4.TurntheselectiondialtotheBoomSelect(orTotal
Area)position.
5.UsetheIncreaseorDecreasecalibrationbuttons
toselecttheboomforwhichyouwishtochange
thewidth,where1istheleftboom,2isthecenter
boom,and3istherightboom.
6.TurntheselectiondialtotheWidth(orSubArea)
position.
7.UsetheIncreaseorDecreasecalibrationbuttonsto
changetheboomwidthasneeded.
8.Repeatsteps4through7fortheotherboomsas
needed.
9.PresstheCalibratebuttonuntiltheredlightturns
off.Youcanalsoexitthecalibrationmodeby
drivingthesprayer.
SettingtheUnitsofMeasure
ThedefaultsettingfortheunitsofmeasureisUS.You
canalsochangetheunitstoSI(metric)orTURF .