EasyManua.ls Logo

Toro 41179 - Page 33

Toro 41179
68 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1.Stopthesprayerandsettheparkingbrake.
2.SetthemasterboomswitchtotheOffposition.
Themonitordisplays“HOLD”.
3.PressandholdtheCalibratebuttonuntilthe
monitordisplays“CALHOLD”andtheredlight
onthemonitorilluminates.
4.TurntheselectiondialtotheSelectUnits(orUnits
ofMeasure)position.
5.UsetheIncreaseorDecreasecalibrationbuttonsto
selectdesiredunitsofmeasure.
6.PresstheCalibratebuttonuntiltheredlightturns
off.Youcanalsoexitcalibrationmodebydriving
thesprayer.
CalibratingtheFlowmeter
Note:Performthiscalibrationprocedureeachtime
nozzlesarechangedtoensurethegreatestaccuracy.
TheSprayPromonitorcomesapproximatelycalibrated
fortheowmeter.Completethefollowingprocedure
tonetunetheowmetercalibration:
1.Settheparkingbrake.
2.Fillthesprayertankwithaknownquantityofwater,
atleast100USgallons(380L).
Note:Donotrelyonthemarksonthesideofthe
tankformeasuringthewaterforthisprocedure.
Theyareapproximatemeasurements,butnot
accurateenoughforthiscalibration.
3.SetthepumpswitchtotheOnpositiontostart
thepump.
4.Setallthreeboomswitchesandthemasterboom
switchtotheOnposition.Runtheboomsonly
untiltheairispurgedfromtheline,thenturnthem
offusingthemasterboomswitch.
5.TurntheselectiondialtotheTotalVolumeposition.
6.PressandholdtheResetcalibrationbuttonuntil
thedisplayreads“0”.
7.SetthemasterboomswitchtotheOnpositionand
runtheboomsuntilallthewaterisoutofthetank,
thenstopthemusingthemasterboomswitch.
8.Comparethevolumedisplayedonthemonitorto
thevolumeofwateryouputintothetank.
Ifthevolumesarethesame,youdonotneedto
calibratethemonitoranyfurther.
Ifthevaluesaredifferent,continuewiththerest
ofthisprocedure.
9.WiththeselectiondialsettotheTotalVolume
position,pressandholdtheCalibratebuttonuntil
themonitordisplays“CALHOLD”andthered
lightonthemonitorilluminates.
Thedisplaywillalternatebetweenthetotalvolume
reading(“HOLD”shown)andtheowcalibration
value(“CALHOLD”shown).
10.Whenthetotalvolumevalueisdisplayed,usethe
IncreaseorDecreasecalibrationbuttonstochange
ittotheamountofwateryouputinthetank.
11.Whenthedisplaybeginsalternatingagain,the
owcalibrationvaluewillhavechanged;writethis
numberdownandsaveit.Thisisthecalibration
valueforyoursprayer.
12.PresstheCalibratebuttonuntiltheredlightturns
off.Youcanalsoexitcalibrationmodebydriving
thesprayer.
CalibratingtheSpeedSensor
TheSprayProcomesapproximatelycalibratedforthe
speedsensor.Completethefollowingproceduretone
tunethespeedsensorcalibration:
1.Checkandllalltires;refertoCheckingTire
PressureintheDriveSystemMaintenancesection.
2.Fillthefreshwatertank.
3.Fillthesprayertankhalf-fullofwater.
4.Selectastraight,attrackofgroundthatissimilar
toyourturfconditions.
Note:Usingaroadorotherpavedsurfacecould
causeaninaccuratereadingwhenyoulaterdrive
thesprayeronturf.
5.Measure500feet(150m),markingboththestart
andendpoints.
6.Positionthesprayeratthestartingpoint.
7.Setthepumpandthemasterboomswitchesto
theOffposition.Themonitorshoulddisplay
“HOLD”.
8.TurntheselectiondialtotheDistanceposition.
9.PressandholdtheResetcalibrationbuttonuntil
thedisplayreads“0”.
10.Pressthemasterboomswitchtostartthedistance
trackingwiththemonitor.Drivethemachinefrom
thestartpointyoumarkedtothe500feet(150m)
endpoint.
11.Stopattheendpoint,setthemasterboomswitch
totheOffpositiontostopthemonitor.
12.Lookatthedistancedisplayedonthemonitor.
Ifitreads“500feet(150m)”,youdonotneed
tocalibratethemonitoranyfurther.
Ifitdoesnotread“500feet(150m)”,continue
withtherestofthisprocedure.
13.Settheparkingbrake.
33

Table of Contents

Related product manuals