EasyManua.ls Logo

Toro 41179 - Page 61

Toro 41179
68 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Problem
PossibleCauseCorrectiveAction
1.Thespeedsensorisnotcalibrated
correctly.
1.Calibratethespeedsensor.
TheDistanceisinaccurate.
2.Thespeedsensorisdamaged.
2.ContactyourAuthorizedService
Dealer.
1.Themonitorcableisloose.
1.Connectthemonitorcable.
2.Theowmeterisdirtyorclogged.2.Cleantheowmeter.
3.Theowmeterisnotcalibrated
correctly.
3.Calibratetheowmeter.
ThemonitordoesnotdisplayApplication
RateorTotalVolume.
4.Theowmeterisdamaged.4.ContactyourAuthorizedService
Dealer.
1.Theowmeterisdirtyorclogged.1.Cleantheowmeter.
2.Theowmeterisnotcalibrated
correctly.
2.Calibratetheowmeter.
TheT otalVolumeisinaccurate.
3.Theowmeterisdamaged.3.ContactyourAuthorizedService
Dealer.
Themonitordisplays6553.5wheninthe
ApplicationRatesetting.
1.Themonitorisnotreceivingdatafrom
thespeedsensor.
1.ContactyourAuthorizedService
Dealer.
Themonitoriserraticinoperation.1.Atwo-wayradioistooclosetothe
monitororitscables.
1.Keeptwo-wayradiosawayfromthe
monitoranditscables.
Thedisplayedmeasurementsdonotmake
sense.
1.TheUnitsofMeasurementissettoa
systemotherthanwhatyouexpect.
1.ChecktheUnitsofMeasurementto
ensurethatitissetcorrectly.
Themonitorreads“OFL.”
1.Thedatahasexceededthemaximum
allowed.
1.Pressandholdthe[Reset]buttonto
clearthemonitor.
61

Table of Contents

Related product manuals