EasyManua.ls Logo

Toro Groundsmaster 3400 - Cooling and Hydraulic Fluid Checks

Toro Groundsmaster 3400
52 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CheckingtheCoolingSystem
ServiceInterval:Beforeeachuseordaily
CAUTION
Iftheenginehasbeenrunning,thepressurized,hot
coolantcanescapeandcauseburns.
Donotopentheradiatorcapwhentheengine
isrunning.
Usearagwhenopeningtheradiatorcap,and
openthecapslowlytoallowsteamtoescape.
Thecoolingsystemislledwitha50/50solutionofwater
andpermanentethyleneglycolantifreeze.
1.Cleananydebrisoffthescreen,oilcooler,andthefront
oftheradiatordailyandmoreoftenifconditionsare
extremelydustyanddirty.RefertoRemovingDebris
fromtheCoolingSystem(page38).
2.Checkthelevelofthecoolantintheexpansiontank
(Figure22).
Note:Checkandensurethatthecoolantlevelis
betweenthemarksonthesideofthetank.
1
g025068
g025068
Figure22
1.Expansiontank
3.Ifthecoolantlevelislow,removetheexpansiontank
capandreplenishthesystem.Donotoverll.
4.Installtheexpansiontankcap.
CheckingtheHydraulicFluid
Themachinesreservoirislledatthefactorywith
approximately32L(7.0UKgallons)ofhigh-qualityhydraulic
uid.Checkthelevelofthehydraulicuidbeforeyou
starttheengineforthersttimeanddailythereafter.The
recommendedreplacementuidisasfollows:
ToroPremiumAllSeasonHydraulicFluid(Availablein
19L(5gallon)pailsor208L(55gallon)drums.Seeparts
catalogorT oroDistributorforpartnumbers.)
Alternateuids:IftheTorouidisnotavailable,otheruids
maybeusedprovidedtheymeetallthefollowingmaterial
propertiesandindustryspecications.Wedonotrecommend
theuseofsyntheticuid.Consultwithyourlubricant
distributortoidentifyasatisfactoryproduct.
Note:Torowillnotassumeresponsibilityfordamage
causedbyimpropersubstitutions,souseonlyproducts
fromreputablemanufacturerswhowillstandbehindtheir
recommendation.
HighViscosityIndex/LowPourPointAnti-wearHydraulic
Fluid,ISOVG46
MaterialProperties:
Viscosity,ASTMD445cSt@40°C44to48
cSt@100°C7.9to8.5
ViscosityIndexASTM
D2270
140to160
PourPoint,ASTMD97-34°Fto-49°F
IndustrySpecications:
VickersI-286-S(QualityLevel),VickersM-2950-S
(QualityLevel),DenisonHF-0
Note:Manyhydraulicuidsarealmostcolorless,makingit
difculttospotleaks.Areddyeadditiveforthehydraulic
systemoilisavailablein20ml(2/3oz)bottles.Onebottle
issufcientfor15to22L(4to6gallons)ofhydraulic
uid.OrderPartNo.44-2500fromyourauthorizedToro
distributor.
BiodegradableHydraulicFluid-ToroPremiumSynthetic
BioHydFluid
ToroBiodegradableHydraulicFluid(Availablein5
gallonpailsor55gallondrums.SeepartscatalogorT oro
distributorforpartnumbers).
Note:ToroPremiumSyntheticBioHydFluidistheonly
syntheticbiodegradableuidapprovedbyToro.Thisuidis
compatiblewiththeelastomersusedinTorohydraulicsystems
andissuitableforawiderangeoftemperatureconditions.
Thisuidiscompatiblewithconventionalmineraloils,but
formaximumbiodegradabilityandperformancethehydraulic
systemshouldbethoroughlyushedofconventionaluid.
ContactyourlocalToroDistributorfordetails.
1.Positionthemachineonalevelsurface,lowerthe
cuttingunits,andshutofftheengine.
2.Checkthesightlevelgaugeonthesideofthetank.The
levelneedstobeattheuppermark.
3.Ifhydraulicuidisneeded,cleanareaaroundthecap
ofhydraulictank(Figure23).
4.Removethecapfromthetank.
19