g014452
Figure50
1.Tank-llercap
3.Fillerstrainer
2.Suctionstrainer
CheckingtheHydraulic-Fluid
OverheatWarningSystem
ServiceInterval:Every500hours
g018024
Figure51
1.Temperatureswitch2.Hydraulic-oiltank
1.TurntheignitionkeytotheONposition(I).
2.Disconnectthered/yellowwireterminalfromthe
hydraulictanktemperatureswitch.
3.Touchthemetalterminalofthewireontoasuitable
earthpoint,ensuringthatthemetalsurfacesmake
goodcontact.
Thehornwillsoundandthe
hydraulic-uid-temperature-warninglightwillilluminateto
conrmcorrectoperation.Ifnecessary,makerepairsbefore
operatingthemower.
CheckingtheHydraulicLines
andHoses
Daily,checkhydrauliclinesandhosesforleaks,kinked
lines,loosemountingsupports,wear,loosettings,weather
deterioration,andchemicaldeterioration.Makeallnecessary
repairsbeforeoperatingthemachine.
44