EasyManua.ls Logo

Toro Z Master Z400 Series - Page 70

Toro Z Master Z400 Series
190 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4-5Z Master Z400 Service Manual
4
3. Loosely install the two bolts and nuts retaining the
hydrostatic pump to the frame (Fig. 160).
Fig 160 PICT-0091a Fig 162 PICT-0084a
5. Install the pump suction hydraulic line located on the
front of the hydrostatic pump (Fig. 162).
Fig 161 PICT-0083a
4. Install the case drain hydraulic hose and hose clamp
located on the top inside of the hydrostatic pump
(Fig. 161).
HYDRAULIC SYSTEM
6. Install the two high pressure hydraulic lines located
at the rear of the hydrostatic pump (Fig. 163).
Fig 163 PICT-0086a