Page 8
Mid-range printer: B-SA4TP / B-SA4TM
b) 'Cm/inch counter' reading
Note:
- FW update for 'cm/inch counter' may be required.
o B-SA4T Series, FW version: B-SA_MAIN_C2.1
o B-SA4T Series, Boot version: B-SA_BOOT_1.2A
- The new/additional 'cm/inch counter' is available for use as soon as the new FW is
installed.
- There is no conversion of the previous counter reading in 0.1 km in
MAINTENANCE CONT.
- The '0.1 km' counter in MAINTENANCE CONT is not added to the 'cm/inch
counter.'
1. The system is in ONLINE mode
when switched on.
2. Press the [PAUSE] key.
3. [PAUSE] is shown on the display.
4. Hold the [FEED] key down
until the counter is shown on
the display.
6. Press the [RESTART]
key to choose between
'cm' and 'inch.’
7. Press the [PAUSE] key to print out the
counter reading. The Normal mode in
Step 1 is shown again once printing is
complete. If you do not wish for the
counter reading to be printed, press
the [FEED] key to display the Normal
mode in Step 1.

Other manuals for Toshiba B-EX6T1