e-STUDIO520/600/720/850 ADJUSTMENT March 2005 © TOSHIBA TEC
3 - 2
(4) After about two minutes and 30 seconds, the value B automatically starts changing.
Fig.3-3
(5) After a short time, the value B becomes stable and the display changes as follows.
Fig.3-4
(6) Press the [ENTER] or [INTERRUPT] button. The drum, developer unit, etc. are stopped and the
following is displayed.
The drum, developer unit, etc. are stopped and the following is displayed.
Fig.3-5
(7) Standard of adjustment value range
(8) Key in code [290] and press the [START] button. When the message "WAIT" goes off, turn the
power OFF by shutdown.
(9) Install the toner cartridge.
Humidity(%) Adjustment reference voltages(V)
0 to 29.9 2.46
30.0 to 44.9 2.48
45.0 to 59.9 2.50
60.0 to 74.9 2.64
75.0 to 100 2.78