e-STUDIO520/600/720/850 ADJUSTMENT March 2005 © TOSHIBA TEC
3 - 58
3.11.2 Adjustment of RADF height
It is mainly performed at the installation. It is also required when the RADF is dislocated for some rea-
son such as moving the equipment.
Perform the following adjustment by using the screw of the left and right hinge.
Note: Note:
Perform this adjustment after “3.11.1 Adjustment of RADF position”.
Turn the exposure lamp ON during the gap check. (Test Mode: 03-267)
<Procedure>
(1) Adjustment standard
Adjust the height so that the platen guide holder touches the ADF original glass.
(Adjust after removing the top left cover.)
Fig.3-60
(2) Adjust the height of the hinge by turning the height adjusting screw on the hinge.
CW: The height of the hinge becomes high.
CCW: The height of the hinge becomes low.
Fig.3-61
0 mm
Platen guide holder
ADF original glass ADF original glass
Platen guide holder
0 mm
Adjustment screw