EasyManua.ls Logo

Toshiba E-STUDIO600 - Image Density Adjustment

Toshiba E-STUDIO600
592 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
e-STUDIO520/600/720/850 ADJUSTMENT March 2005 © TOSHIBA TEC
3 - 28
<Procedure>
(1) While pressing [0] and [5] simultaneously, turn the power ON.
(2) Key in the codes to be adjusted (language and screen) and press the [START] button.
(3) Key in the value corresponding to the density area to be adjusted (0, 1 or 2) and press the
[START] button.
0: Low density (L) 1: Medium density (M) 2: High density (H)
(4) Key in the adjustment value. (To correct the value once keyed in, press [CLEAR] button.)
(5) Press the [ENTER] or [INTERRUPT] button to store the value in memory. ¨ The equipment goes
back to the ready state.
(6) For resetting the value, repeat step (2) to (5).
(7) Let the equipment restart and perform printing job.
(8) If the image density has not been attained, repeat step (1) to (7).
3.4.3 Image density adjustment
Adjust the image density level when normal printing (Toner save: Disable) and (Toner save: Enable).
< Adjustment Mode (05) >
<Procedure>
Procedure is same as that of P.3-27 "3.4.1 Adjustment of smudged/faint text".
Normal
Toner Saving
mode
Item to be adjusted Remarks
PS/PCL PS PCL
663 664 665 Image density adjustment The image density level in the Printer function can
be set.
The smaller the value is, the lighter the density of
image becomes.
Acceptable values: 0 to 255.