EasyManua.ls Logo

Toshiba E-STUDIO600 - Adjustment Mode (05)

Toshiba E-STUDIO600
592 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
e-STUDIO520/600/720/850 ERROR CODE AND SELF-DIAGNOSTIC MODE March 2005 © TOSHIBA TEC
2 - 40
2.2.4 Adjustment mode (05)
Procedure 1
Procedure 2
Procedure 3
Procedure 4
Items in the adjustment mode list in the following pages can be corrected or changed in the adjust-
ment mode (05). Turn ON the power with pressing the digital keys [0] and [5] simultaneously in
order to enter this mode.
When the power should be turned OFF, be sure to shut down the equipment by pressing the
[ENERGY SAVER] button for a few seconds.
[0][5]
[POWER]
[POWER]
OFF/ON
(Exit)
[Digital key]
(Code)
[START]
[CANCEL]
[Digital key]
*
[FUNCTION CLEAR]
(Key in a value)
[CLEAR]
(Corrects value)
[ENTER]
or
[INTERRUPT]
(Stores value in RAM)
([FAX]
or
[COPY])
(Test copy)
*Press [
FUNCTION CLEAR
] to enter minus (-).
[0][5]
[POWER]
[POWER]
OFF/ON
(Exit)
(Code)
[START]
[ENTER]
or
[INTERRUPT]
(Value unchangeable)
([FAX]
or
[COPY])
(Test copy)
Value
displayed
( )
[0][5]
[POWER]
[POWER]
OFF/ON
(Exit)
[Digital key]
(Code)
[START]
[CANCEL]
[UP]
or
[DOWN]
(Adjust a value)
[CLEAR]
(Corrects value)
[ENTER]
or
[INTERRUPT]
(Stores value in RAM)
([FAX]
or
[COPY])
(Test copy)
[0][5]
[POWER]
[POWER]
OFF/ON
(Exit)
[Digital key]
(Code)
[Digital key]
*
[FUNCTION CLEAR]
[START]
[START]
[Digital key]
(Sub code)
[CLEAR]
(Corrects value)
[CLEAR]
(Corrects value)
[ENTER]
or
[INTERRUPT]
*Press [FUNCTION CLEAR] to enter minus (-).
(Key in a value)
Stores value
in RAM
( )
([FAX]
or
[COPY])
(Test copy)
[CANCEL]
[START]

Table of Contents

Related product manuals