March 2005 © TOSHIBA TEC e-STUDIO520/600/720/850 ADJUSTMENT
3 - 85
3
3.16 Adjustment of LCF (MP-4004)
3.16.1 Sheet sideways deviation adjustment
When the center of the printed image shifts to the front side or rear side, adjust the tray position taking
the following procedure.
<Procedure>
(1) Pull out the tray unit.
(2) Loosen 3 screws and move the adjustment board to the right position. Then screw it shut.
Fig.3-92
The center of the printed image shifts to the front side:
Move the adjustment board to the front side (Arrow (B) in the upper figure).
Fig.3-93
A B
Adjustment board
Feeding direction
Center
[
Rear
]
[
Front
]