5.1.17 Troubleshooting for remaining toner detection sensor
Take an appropriate countermeasure for the following cases:
When a message notifying the toner cartridge needs to be replaced is displayed and the cartridge is
replaced accordingly, but the message remains displayed
When a message notifying the toner cartridge needs to be replaced is displayed and the equipment
simultaneously stops its operation during the process of a job (The equipment should keep its oper-
ation for a while even if such message is displayed.)
The Auto Supply Order function does not work.
Countermeasure
1) Check if the connector or connector pins on the toner drive are disconnected.
2) Replace the remaining toner detection sensor.