March 2005 © TOSHIBA TEC e-STUDIO520/600/720/850 ADJUSTMENT
3 - 17
3
[C] Image position adjustment of the primary scanning direction
<Procedure>
(1) While pressing [0] and [5] simultaneously, turn the power ON. ! (Adjustment Mode)
(2) Place a ruler on the original glass with its leading edge pushed against the rear side and its side
along the original scale on the left.
(3) Press [COPY] to make a copy at the mode of A3 (LD), 100% and the 2nd/4th drawer.
(4) Measure the distance B from the left edge of the paper to 100 mm of the copied image of the
ruler.
(5) Check if the distance B is within the range of 100±1.0 mm.
(6) If not, use the following procedure to change values and repeat the steps (3) to (5) above.
(Adjustment Mode) ! (Key in the code [306]) ! [START]
! (Key in a value (acceptable values: 0 to 255))
! Press the [ENTER] or the [INTERRUPT] button (stored in memory).
! (“100% A” is displayed.)
* The smaller the adjustment value is, the more the image is shifted to the left and the distance
B becomes narrower (0.169 mm/step).
Fig.3-17
50 100 150 200
B
Feeding direction
Copied image of the ruler