March 2005 © TOSHIBA TEC e-STUDIO520/600/720/850 ADJUSTMENT
3 - 19
3
[E] Image position adjustment of the secondary scanning direction
<Procedure>
(1) While pressing [0] and [5] simultaneously, turn the power ON. ! (Adjustment Mode)
(2) Place a ruler on the original glass with its leading edge pushed against the original scale on the
left.
(3) Press [COPY] to make a copy at the mode of A3 (LD), 100% and the 2nd/4th drawer.
(4) Measure the distance D from the leading edge of the paper to 10 mm of the copied image of the
ruler.
(5) Check if the distance D is within the range of 10±2.0 mm.
(6) If not, use the following procedure to change values and repeat the steps (3) to (5) above.
(Adjustment Mode) ! (Key in the code [305]) ! [START]
! (Key in a value (acceptable values: 0 to 255))
! Press the [ENTER] or the [INTERRUPT] button (stored in memory).
! (“100% A” is displayed.)
* The larger the adjustment value is, the more the image is shifted to the trailing edge (0.143
mm/step).
Fig.3-19
10 20 30 40
D
Feeding direction
Copied image of the ruler