e-STUDIO520/600/720/850 ADJUSTMENT March 2005 © TOSHIBA TEC
3 - 22
[H] Bottom margin
<Procedure>
(1) While pressing [0] and [5] simultaneously, turn the power ON. ! (Adjustment Mode)
(2) Open the RADF.
(3) Press the [FAX] to make a copy at the mode of A3/LD, 100%, Text/Photo and the 2nd/4th drawer.
(4) Measure the blank area G at the trailing edge of the copied image.
(5) Check if the blank area G is within the range of 2±1.0 mm.
(6) If not, use the following procedure to change values and repeat the steps (3) to (5) above.
(Adjustment Mode) ! (Key in the code [433]) ! [START]
! (Key in value (acceptable values: 0 to 255))
! Press the [ENTER] or the [INTERRUPT] button (stored in memory).
! (“100% A” is displayed.)
* The larger the adjustment value is, the wider the blank area at the trailing edge becomes
(approx. 0.04 mm/step).
Fig.3-22
G
Feeding direction