e-STUDIO520/600/720/850 ADJUSTMENT March 2005 © TOSHIBA TEC
3 - 60
(2) Step 2
Case C:
Loosen 2 fixing screws and then turn the adjustment screw counterclockwise.
Case D:
Loosen 2 fixing screws and then turn the adjustment screw clockwise.
Note: Note:
When adjusting, refer to the hinge position (scribed line) and be sure not to move it from the
hinge position ±0.5 mm or further. Otherwise, image failures such as a jitter may occur.
Fig.3-65
Fig.3-66
C D
Paper
Original
Adjustment screw