e-STUDIO520/600/720/850 PREVENTIVE MAINTENANCE (PM) March 2005 © TOSHIBA TEC
4 - 2
[ 2 ] Operational screen
1) Main screen
Fig.4-2
Displaying of the main unit name
Back to the PM support mode activation screen
Moving to the clear screen to clear the selected unit counters ( and ), including all sub
unit (parts) counters belonging to that unit
When the unit is not selected, all counters are cleared.
Moving to the sub screen of the selected unit
Moving to the next/previous page
Displaying of the present number of output pages counts (x 1,000)
When there are differences among the sub units (parts), “_” is displayed and “CHECK SUB-
UNIT” is displayed at the top
“*” is displayed next to the present number when the number of output pages counts has
exceeded its PM standard number.
Displaying of the standard number of output pages counts (x 1,000) to replace the unit parts
Displaying of the present drive counts (x 1,000)
“*” is displayed next to the present number when the number of drive counts has exceeded its
PM standard number.
Displaying of the standard number of drive counts (x 1,000) to replace the unit parts
Displaying of the number of output pages counts (Cpy.), drive counts (Cnt.) and previous
replacement date (Chg.) for a chosen unit.
When the replacement date for the sub unit is different, press the [SUB UNIT] button to move
to the sub screen and see each information, otherwise information is not displayed
10