e-STUDIO520/600/720/850 TROUBLESHOOTING March 2005 © TOSHIBA TEC
5 - 2
l
l
l
l
l
l
l
l
l
!
NO " 1) Check if the connector of the drum separation finger solenoid is dis-
connected.
2) Check if the connector CN339 on the LGC board is disconnected.
3) Check the installation state of cleaner.
4) Is the relay connector connecting the cleaner unit and the equipment
disconnected or stained with toner?
5) Replace the drum separation finger solenoid.
6) Replace the LGC board.
YES
Is the registration sensor working?
(Perform the input check in the test mode: 03-[FAX]ON/[4]/[E])
l
l
l
l
l
l
l
l
l
l
l
!
NO " 1) Check if the connector of the registration sensor is disconnected.
2) Check if the registration sensor is installed correctly.
3) Check if the registration actuator is operating properly.
4) Check if the connector CN341 on the LGC board is disconnected.
5) Check if the connector pins are disconnected and the harnesses are
open circuited.
6) Check if the conductor pattern on the LGC board is short circuited or
open circuited.
7) Replace the registration sensor.
8) Replace the LGC board.
YES
Is the registration motor working?
(Perform the output check in the test mode: 03-108/158)
l
l
l
l
l
l
l
l
l
!
NO " 1) Check if the connector of the registration roller clutch is discon-
nected.
2) Check if the connector CN341 on the LGC board is disconnected.
3) Check if the connector pins are disconnected and the harnesses are
open circuited.
4) Check if the conductor pattern on the LGC board is short circuited or
open circuited.
5) Replace the registration roller clutch.
6) Replace the LGC board.
YES
Check if there is any abnormality in the space between the registration motor and the regis-
tration roller (metal).
Check if the registration roller (rubber) is rotating smoothly.
Check the condition of the registration roller at the horizontal transport section and clean or
replace it.
* If the error [E010] caused by a paper jam underneath the drum cleaner often occurs due
to an insufficient paper separation from the photoconductive drum, set a smaller value in
the code 08-841, and see what happens. At this time, however, pay attention to the
transferability at the leading edge of the paper since this transferability can be slightly
narrowed depending on the environments and conditions under which the equipment is
placed or the media type of the paper used. (Refer to 3.6.1 in this manual about the
details of the code 08-841.)