e-STUDIO520/600/720/850 ERROR CODE AND SELF-DIAGNOSTIC MODE March 2005 © TOSHIBA TEC
2 - 70
Notes:
The digit after the hyphen in “Code” of the following table is a sub code.
In “RAM”, the NVRAM or FRAM of the board in which the data of each code is stored is indi-
cated. “M” stands for the LGC board, “SYS” and “UTY” stands for the SYS board.
Setting mode (08)
Code
Classifi-
cation
Items
Func-
tion
Default
<Accept-
able
value>
RAM Contents
Proce-
dure
200 General Date and time setting ALL -
<13 dig-
its>
- Year/month/date/day/
hour/minute/second
Example:
03 07 0 13 13 27 48
“Day” - “0” is for
“Sunday”. Pro-
ceeds Monday
through Saturday
from “1” to “6”.
5
201 General Destination selection ALL EUR: 0
UC: 1
JPN: 2
<0-2>
M 0: EUR
1: UC
2: JPN
1
202 User
interface
Counter installed externally ALL 0
<0-3>
M 0: No external counter
1: Coin controller
2: Copy key card
3: Key copy counter
1
203 General Line adjustment mode ALL 0
<0-1>
M 0: For factory shipment
1: For line
* Field: “0” must be
selected
1
204 User
interface
Auto-clear timer setting ALL 3
<0-10>
SYS Timer to return the
equipment to the
default settings when
the [START] button is
not pressed after the
function and the mode
are set
0: Not cleared
1 to 10: Set number x
15 sec.
1
205 User
interface
Auto power save mode
timer setting
ALL 11
<0, 6-15>
SYS Timer to automatically
switch to the Auto
power save mode when
the equipment has not
been used
0: Invalid 6: 3min.
7: 4min. 8: 5min.
9: 7min.
10: 10min.
11: 15min.
12: 20min.
13: 30min.
14: 45min.
15: 60min.
1

Table of Contents