7
Introduction
Components
1
1. Outdoor unit
Corresponding HP Inverter unit Fixed-speed unit
8 HP 10 HP 6 HP 8 HP 10 HP
Model name MM-A0224HT MM-A0280HT MM-A0160HX MM-A0224HX MM-A0280HX
Cooling capacity (kW) 22.4 28.0 16.0 22.4 28.0
Heating capacity (kW) 25.0 31.5 18.0 25.0 31.5
Corresponding HP Inverter unit Fixed-speed unit
8 HP 10 HP 6 HP 8 HP 10 HP
Model name MM-A0224CT MM-A0280CT MM-A0160CX MM-A0224CX MM-A0280CX
Cooling capacity (kW) 22.4 28.0 16.0 22.4 28.0
2. Outdoor units (combination of outdoor units)
Corresponding HP 8HP 10HP 14HP 16HP 18HP 20HP 22HP 24HP 26HP 28HP 30HP 32HP 34HP 36HP 38HP 40HP 42HP 44HP 46HP
Combined model
MM-A-HT/MM-A-CT 0224 0280 0384 0440 0504 0560 0608 0672 0728 0784 0840 0896 0952 1008 1064 1120 1176 1232 1288
Cooling capacity (kW) 22.4 28.0 38.4 44.8 50.4 56.0 60.8 67.2 72.8 78.4 84.0 89.6 95.2 100.8 106.4 112.0 117.6 123.2 128.8
Inverter unit 8HP 10HP 8HP 8HP 10HP 10HP 8HP 8HP 10HP 10HP 10HP 8HP 10HP 10HP 10HP 10HP 10HP 10HP 10HP
Combined Fixed-speed - - 6HP 8HP 8HP 10HP 8HP 8HP 8HP 10HP 10HP 8HP 8HP 10HP 10HP 10HP 8HP 10HP 10HP
outdoor units unit - -----6HP8HP8HP8HP10HP 8HP 8HP 8HP 10HP 10HP 8HP 8HP 10HP
-----------8HP8HP8HP8HP10HP 8HP 8HP 8HP
----------------8HP8HP8HP
No. of connectable
indoor units 13 16 16 18 18 20 22 24 26 28 30 32 34 36 38 40 40 40 40
Min. HP connected 4 57891011121314151617181920212223
Max. HP connected 10.8 13.5 18.9 21.6 24.3 27 29.7 32.4 35.1 37.8 40.5 43.2 45.9 48.6 51.3 54 56.7 59.4 62.1
3. Branching joints/headers
Model name Usage Appearance
Y-shape branching joint RBM-Y018-SK Indoor unit capacity code (*1): Total < 6.4
RBM-Y037-SK Indoor unit capacity code (*1): 6.4 = Total < 13.2 (*2)
RBM-Y071-SK Indoor unit capacity code (*1): 13.2 = Total < 25.2 (*2)
RBM-Y129-SK Indoor unit capacity code (*1): 25.2 = Total (*2)
4-branching header (*3) RBM-H4037-SK Indoor unit capacity code (*1): Total < 6.4 Max. 4
RBM-H4071-SK Indoor unit capacity code (*1): 6.4 = Total < 13.2 branches
8-branching header (*3) RBM-H8037-SK Indoor unit capacity code (*1): Total < 6.4 Max. 8
RBM-H8071-SK Indoor unit capacity code (*1): 6.4 = Total < 13.2 branches
T-shape branching joint 1 set of 3 types of T-shape joint pipes as described below.
(For connection of The required quantity is arranged and they are combined at the site.
outdoor unit) RBM-T129-SK
Connecting pipe Corresponding dia. (mm) Quantity
Balancing pipe 9.52 1
Piping at liquid side 12.7 to 22.2 1
Piping at gas side 22.2 to 54.1 1
(*1) Code is determined according to the capacity code of the Indoor units connected.
(*2) If the total capacity code value of Indoor units exceeds that of Outdoor units, apply the capacity code of Outdoor units.
(*3) When using a branch header, Indoor units with a maximum of 6.0 capacity code in total can be connected to each
branch.
NOTE: If the length of the gas pipe exceeds 30m from the 1st branching to an Indoor unit, increase the gas pipe size by
1 size, i.e. MM-U140 = Gas Ø22.2, Liquid Ø9.5