E6581697
G-9
7
(3) The logical product (AND) or logical sum (OR) of the two
functions assigned is put out as a signal.
■ Setting of output terminal function
Ter mi na l
symbol
Title Function Adjustment range Default setting
RY-RC
Output terminal selection 1A
4
(LOW)
OUT Output terminal selection 2A
6
(RCH)
RY-RC Output terminal selection 1B
255
(always ON)
OUT Output terminal selection 2B
0-255
255
(always ON)
0: and
and
1: or
and
2: and
or
RY-RC/
OUT
Output terminal logic selection
3: or
or
0
Two different functions can be assigned to the output terminals (RY-RC and OUT-NO), and two logics with
different functions can be selected using .
The logical product (AND) or logical sum (OR) of the two functions assigned is put out as a signal, depending
on the setting of parameter .
If = , the logical sum (AND) of and will be output to RY-RC.
The logical product (OR) of and will be output to OUT-NO.
If = , the logical product (OR) of and will be output to RY-RC.
The logical sum (AND) of and will be output to OUT-NO.
If = , the logical sum (AND) of and will be output to RY-RC.
The logical product (OR) of and will be output to OUT-NO.
If = , the logical product (OR) of and will be output to RY-RC.
The logical product (OR) of and will be output to OUT-NO.
, To assign only one function to output terminals, assign the function to and while leaving
f137 to f139 as they are set by default.
Note: f138 (OUT-NO): Enable only when f669=0
Disabled and the set value cannot be read out, if f669 is set to 1.