E6581697
K-9
11
Title
Communication
No.
Function Unit
Minimum
setting unit
Panel/Commun
ication
Adjustment range
Default
setting
User
setting
Reference
0260 Jog run frequency Hz 0.1/0.01
-20.0
5.0 6.10
0261 Jog run stopping
pattern
- - 0: Deceleration stop
1: Coast stop
2: DC braking stop
0
0262 Panel jog run
operation mode
- - 0: Invalid
1: Valid
0
0264 External logic
input - UP
response time
s 0.1/0.1 0.0-10.0 0.1 6.6.3
0265 External logic
input - UP
frequency steps
Hz 0.1/0.01 0.0- 0.1
0266 External logic
input - DOWN
response time
s 0.1/0.1 0.0-10.0 0.1
0267 External logic
input - DOWN
frequency steps
Hz 0.1/0.01 0.0- 0.1
0268 Initial value of
UP/DOWN
frequency
Hz 0.1/0.01
0.0
0269 Change of the
initial value of
UP/DOWN
frequency
- - 0: Not changed
1: Setting of changed when
power is turned off
1
0270 Jump frequency 1 Hz 0.1/0.01 0.0- 0.0 6.11
0271 Jumping width 1 Hz 0.1/0.01 0.0-30.0 0.0
0272 Jump frequency 2 Hz 0.1/0.01 0.0- 0.0
0273 Jumping width 2 Hz 0.1/0.01 0.0-30.0 0.0
0274 Jump frequency 3 Hz 0.1/0.01 0.0- 0.0
0275 Jumping width 3 Hz 0.1/0.01 0.0-30.0 0.0
0287 Preset-speed
frequency 8
Hz 0.1/0.01 - 0.0
0288 Preset-speed
frequency 9
Hz 0.1/0.01 - 0.0
0289 Preset-speed
frequency 10
Hz 0.1/0.01 - 0.0
0290 Preset-speed
frequency 11
Hz 0.1/0.01 - 0.0
0291 Preset-speed
frequency 12
Hz 0.1/0.01 - 0.0
0292 Preset-speed
frequency 13
Hz 0.1/0.01 - 0.0
0293 Preset-speed
frequency 14
Hz 0.1/0.01 - 0.0
3.6
6.12
0294 Preset-speed
frequency 15
Hz 0.1/0.01 - 0.0 3.6
6.25
0295 Bumpless
operation selection
- - 0: Disabled
1: Enabled
0 6.13
0298 Factory specific
coefficient 2D
- - - -
* 3
*3: Factory specific coefficient parameters are manufacturer setting parameters. Do not change the value of these parameters.