– 102 – 
  *  To designate the slave station number of the TSL3000E/TSL3100E, observe 
the following steps.    Under [U12] of the USER.PAR (user parameter) file, you 
can find the following parameter setting related to the extension input and 
output. 
    [U12] Extend I/O setting 
{Use/Not Use} (0: Not Use, 1: Use) 
{Not Use} 
{Not Use} 
= 0 28    20   Corresponds to station 0. 
    = 0 28    20   Corresponds to station 1. 
    If you wish to use only station 0 (i.e., one (1) TR48DIOC module), for instance, 
change the underlined bit corresponding to station 0 to "1". 
    = 1 28    20 
    = 0 28    20 
    After saving the parameter file, turn off the controller power and on again.   
Then the above parameter becomes effective. 
    If you wish to use both stations 0 and 1 (i.e., two (2) TR48DIOC modules), 
specify as follows and perform the same operation as above to make the 
parameter valid. 
    = 1 28    20 
    = 1 28    20 
  When using the TR48DIOC module, careful precautions should be taken on the 
following matters.