Software
TOX_Manual_Process-monitoring-unit_CEP400T_en
71
Force sensor with DMS subprint card
Button, input/control panel Function
1 Active Activatingx or deactivatingo the selected
channel.
Deactivated channels are not evaluated
and not displayed in the measurement
menu.
2 Nominal Force The nominal force of the force transducer
corresponds to the force at a maximum
measuring signal.
3 Nominal force, unit Unit of nominal force (maximum of 4
characters)
4 Offset Offset value of the measuring signal for
adjusting a possible zero point offset of
the analog measuring signal of the sen-
sor.
5 Offset limit Maximum tolerated force sensor offset.
6 Forced offset NO: The process monitoring system
ready to measure directly after being
switched on.
YES: The process monitoring system
carries out an offset adjustment for the
respective channel automatically after ev-
ery start.
7 Source Switchover between standard signal and
DMS.
8 Nominal characteristic value Enter the nominal value of the sensor
used.
See the data sheet of the sensor manu-
facturer.
9 Filter Limit frequency of the measurement
channel