Software
72
TOX_Manual_Process-monitoring-unit_CEP400T_en
Button, input/control panel Function
10 Calibrating The force sensor calibration menu opens.
11 Offset adjustment Read in the current measuring signal as
offset of the force sensor.
Setting the nominal force of the force sensor
ü The user is logged in with a suitable user level. The necessary write
permissions are available.
ü The ''Configuration -> Force sensor configuration '' menu is opened.
1. Tap on the Nominal force input field.
w The numerical keyboard opens.
2. Enter the value for the desired nominal force and confirm with ↲.
3. If necessary: Tap on the Nominal force, unit input field.
w The alphanumeric keyboard opens.
4. Enter the value for the desired unit of the nominal force and confirm
with ↲.
Adjusting the offset force sensor
The Offset parameter adjusts a possible zero point offset of the analog
measurement sensor of the sensor.
An offset adjustment must be carried out:
once a day or after approx. 1000 measurements.
when a sensor has been changed.
Adjustment using Offset adjustment button
ü The user is logged in with a suitable user level. The necessary write
permissions are available.
ü The ''Configuration -> Force sensor configuration '' menu is opened.
ü Sensor is load-free during the offset adjustment.
è Tap on Offset adjustment button.
w The current measurement signal (V) is applied as offset.