Software
TOX_Manual_Process-monitoring-unit_CEP400T_en
73
Adjustment via direct Value Input
ü The user is logged in with a suitable user level. The necessary write
permissions are available.
ü The ''Configuration -> Force sensor configuration '' menu is opened.
ü Sensor is load-free during the offset adjustment.
1. Tap on Offset input field.
w The numerical keyboard opens.
2. Enter the zero point value and confirm with ↲.
Offset limit force sensor
Offset limit of 10% means that the "Offset" value must only reach a maxi-
mum of 10% of the nominal load. If the offset is higher, an error message
appears after the offset adjustment. This, for example, can prevent that an
offset is taught when the press is closed.
ü The user is logged in with a suitable user level. The necessary write
permissions are available.
ü The ''Configuration -> Force sensor configuration '' menu is opened.
è Tap on the Offset limit input field.
w Each tap changes the value between 10 -> 20 -> 100.
Forced offset force sensor
If the forced offset is activated, an offset adjustment is carried out automati-
cally after the process monitoring system is switched on.
ü The user is logged in with a suitable user level. The necessary write
permissions are available.
ü The ''Configuration -> Force sensor configuration '' menu is opened.
è Tap on the Forced offset input field.
w Each tap changes the value from YES to NO and reverse.