Software
TOX_Manual_Process-monitoring-unit_CEP400T_en
75
Fig.22 ''Enter Configuration -> Configuration of force sensor\Nominal force''
Button, input/control panel Function
1 Signal
2 Force
3 Force 1
4 Teach 1
5 Measuring value 1 Is faded in when Teach 1is tapped. Dis-
play/Input field of measured value.
6 Force 2
7 Teach 2
8 Measuring value 2 Is faded in when Teach 2is tapped. Dis-
play/Input field of measured value.
9 Nominal Force
10 Offset
11 Accept calibration The calibration of the sensors is ac-
cepted.
12 Accept Saves the changes