76
TOX_Manual_Process-monitoring-unit_CEP400T_en
ü The user is logged in with a suitable user level. The necessary write
permissions are available.
ü The ''Enter the Configuration -> Force sensor configuration\Nominal
force'' menu is opened.
1. Move to the first point, e.g. press opened.
2. Determine the applied force (e.g. by a reference sensor attached tem-
porarily to the press) and simultaneously if possible tap the Teach 1
button for reading the applied force.
w The applied electrical signal is read in.
3. Tap on the Force 1 display/input field.
w The numerical keyboard opens.
4. Enter the value of the measuring value of the electrical measuring sig-
nal to be displayed and confirm with .
5. Move to the second point, e.g. closing the press with a certain press
force.
6. Determine the currently applied force and simultaneously if possible tap
the Teach 2 button for reading the applied force.
w The current electrical measuring signal is accepted and displayed
in a new display/input field Measuring value 2 next to the Teach 2
button.
7. Tap on the Force 2 display/input field.
w The numerical keyboard opens.
8. Enter the value of the measuring value of the electrical measuring sig-
nal to be displayed and confirm with .
9. Save the changes with Accept calibration.
u When pressing the Accept calibration button the process monitoring
system calculates the parameters of nominal force and offset from the
the two force values and the measured electrical signals. That con-
cludes the calibration.