Software
92
TOX_Manual_Process-monitoring-unit_CEP400T_en
The function of an input or output is described in plain text.
Activating or deactivating output
ü The user is logged in with a suitable user level. The necessary write
permissions are available.
ü Menu ''Supplement -> In-Outputs | Internal digital I/O'' is opened.
è Tap on the button below the desired input or output.
u The field changes from red to green or green to red.
u The input or output is activated or deactivated.
u The change becomes effective immediately.
u The change remains effective until the ''Inputs/outputs'' menu is exited.
Change byte
ü The user is logged in with a suitable user level. The necessary write
permissions are available.
ü Menu ''Supplement -> In-Outputs | Internal digital I/O'' is opened.
è Tap the cursor button at the top edge of the screen.
u The byte changes from ''0'' to ''1'' or reverse.
BYTE Bit
0 0 - 7
1 8 - 15
Check field bus In-/Outputs
In menu ''Supplement -> In-/Outputs I Field bus I/O'' the current status of
the field bus inputs and outputs can be checked.
Status:
Active: The corresponding input or output is marked with a green
square.
Not active: The corresponding input or output is marked with a red
square.