EasyManua.ls Logo

TR-Electronic CDH582 - Checklist, Part 2 of 2

Default Icon
91 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Printed in the Federal Republic of Germany TR-Electronic GmbH 2020, All Rights Reserved
10/07/2020 TR-ECE-BA-GB-0163 v03 Page 89 of 91
14 Checklist, Part 2 of 2
We recommend that you print out and work through the checklist for commissioning, replacing the
measuring system and when changing the parameterization of a previously accepted system and
store it as part of the overall system documentation.
Documentation reason Datum edited checked
Sub-item Note Reference yes
Checklist, part 1 of 2
Document no.:
TR-ECE-BA-GB-0142
This User Manual was read and
understood
Document no.:
TR-ECE-BA-GB-0163
Verify that the measuring system
can be used for the present
automation task based on the
specified safety requirements
Safety functions of the fail-safe
processing unit
Compliance with all technical
data
Chapter
Safety functions of the fail-
safe processing unit,
Page 16
Product data sheets
www.tr-
electronic.com/s/S022978
Supply voltage
The power supply unit used
must meet the requirements of
Chapter Supply voltage,
Page 21
Proper
EtherNet/IP
installation
Compliance with valid
international standards or ODVA
guidelines specified for
EtherNet/IP
Chapter
Installation / Preparation for
Commissioning,
from Page 18
Compliance with the safety-
related requirements when using
CIP Safety devices according
to ODVA EtherNet/IP
Specification V2.20, Volume 5,
CIP
Safety, Table “TST97
Safety Manual Inspection
Requirement”
Applicable to
Device replacement
Security connections with
SCID = 0
SNN No. Assignment
SNCT tool configuration
comparison of SCID and
configuration data
Validation of all downloads
Verification of the signature
Verification of configuration data
Function test
Deletion of an existing
configuration
Programming the TUNID
Various SIL levels in the network
Verification of safety connections
Status EDS
Automatic SNN assignment
Locking of configuration data
Ownership assignment for Type
1 SafetyOpen configurations
Visual review of configuration
data
Chapter
Safety-related requirements
when using CIP Safety™
devices
, Page 14
and references
. . .

Table of Contents

Other manuals for TR-Electronic CDH582