10 RT-SVX36K-EN
Model Number Descriptions
DIGIT 18 - ZONE SENSOR
0 = None
A = Dual Setpoint Manual or Auto
Changeover (BAYSENS108*)
B = Dual Setpoint Manual or Auto
Changeover w/ System Function
Lights (BAYSENS110*)
C = Room Sensor w/ Override and
Cancel Buttons (BAYSENS073*)
D = Room Sensor w/Temperature
Adjustment and Override and
Cancel Buttons (BAYSENS074*)
L = Programmable Zone Sensor w/
System Function Lights for both
CV and VAV (BAYSENS119*)
Note: *Asterisk indicates current model
number digit A, B, C, etc. These
sensors can be ordered to ship
with the unit.
DIGIT 19 - AMBIENT CONTROL
0 = Standard
DIGIT 20 - AGENCY APPROVAL
0 = None (cULus Gas Heater, see note)
1 = cULus
Note: Includes cULus classified gas
heating section only when second
digit of Model No. is a "F."
DIGITS 21 - 38 -
MISCELLANEOUS
21 A = Unit Disconnect Switch
22 B = Hot Gas Bypass
23 C = Economizer Control w/
Comparative Enthalpy
23 Z = Economizer Control w/
Reference Enthalpy
23 W = Economizer Control w/Dry Bulb
24 E = Low Leak Outside Air Dampers
25 F = High DuctTemperature
Thermostat
26 G = High Capacity Evap. Coil
(105Ton)
H = High Cap. Evap. Coil and High
Eff. Cond. Coil (90 Ton)
27 0 = Air-Cooled Aluminum
Condenser Coil
J = Corrosion-Protected
Condenser Coil
28 K = Generic B.A.S Module
R = Rapid Restart
29 A = Motors w/ Internal Shaft
Grounding
30 M = Remote Human Interface
31 N = Ventilation Override Module
32 0 = None
R = Extended Grease Lines
1 = Differential Pressure Gauge
2=
Extended Grease Lines and
Differential Pressure Gauge
33 0 = Standard Panels
T = Access Doors
U = IRU - w/ Std Panels
W = IRU - w/ Access Doors
Y = IRU w/SST - w/ Std Panels
34 V = Inter-Processor
Communication Bridge
35 Y = Trane Communication Interface
(TCI) Module
M = BACnet Communication
Interface (BCI) Module
7 = Trane LonTalk Communication
Interface (LCI) Module
37 6 = Factory-Powered 15A GFI
Convenience Outlet
Tip: EXAMPLE
Model numbers:
SXHK*1140AH8CECD8001**Z
describes a unit with the following
characteristics:
DX cooling with extended casing,
no heat, 105 ton nominal cooling
capacity, 460/60/3 power supply,
100 percent exhaust with Statitrac,
30 h.p. exhaust fan motor with
drive selection No. 8 - (800 RPM),
high-efficiency throwaway filters,
50 hp supply fan motor with 1200
RPM, economizer, w/ reference
enthalpy control, Supply and
Exhaust with VFD but no bypass,
cULus agency approval.
The service digit for each model
number contains 36 digits; all 36
digits must be referenced.

Table of Contents

Other manuals for Trane IntelliPak

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Trane IntelliPak and is the answer not in the manual?

Trane IntelliPak Specifications

General IconGeneral
BrandTrane
ModelIntelliPak
CategoryAir Conditioner
LanguageEnglish

Related product manuals