10-4
CLASS C & B
+
MOTORHOME
10.2.3 GENERATOR OPERATION
Refer to the Generator operation and maintenance
information in the Owner's Information Package
1. Controls:
The generator switch is located in the Monitor
Panel in the overhead cabinet. The generator
starter draws current from the coach batteries.
2. Starting:
a. See Generator Manufacturer's Manual for
specific instructions.
IMPORTANT Check the oil level
regularly during frequent use of the
generator.
b. The Motorhome is equipped with an automatic
transfer switch which will switch to the
generator power as soon as the Generator is
running.
c. Disconnect all electrical loads. (Turn off all
lights, appliances, equipment, etc.).
d. Press the top portion of the generator button,
hold until engine is running, then release.
e. Wait for the engine to run smoothly before
turning on the lights and appliances.
f. Be familiar with the output capacity and
capability of your generator.
g. Be careful not to overload the generator. See
your manual for information.
CAUTION
Overloading the generator for long periods of time
can cause high temperatures that could result in
damage to the generator windings. Keep electrical
loads within the wattage ratings specified in your
manual.
3. Stopping:
a. Turn off lights and all appliances before
shutting off engine. Let the engine run at no-
load for a few minutes to allow the engine to
cool down.
b. Press the bottom portion of the generator
button and hold until engine comes to a
complete stop.
GENERATOR CONTROL