CLASS B
+
& C MOTORHOME
81
12.3.2 TOILET
Refer to manufacturer's operating instructions included in information package for more details.
Troubleshooting:
1. Water keeps running into the bowl:
Check to see that the levers return all the way to the left. Sticking may be caused by foreign material on the waste valve
blade or blade seal at the bottom of the bowl. If problem persists, replace water valve.
2. Toilet leaks, there is water on the oor:
If the leak is in back of the toilet, check the water supply line connection and refer to the installation instructions. If
the leak is at the closet ange area, check the closet ange nuts for tightness. If leak continues, remove the toilet and
check the closet ange height. The height should be between 1/4" and 7/16" above the oor. Adjust accordingly and
replace the closet ange seal if damaged.
3. Poor Flush:
The levers must be held fully open during the ush. A good ush should be obtained within 2 to 3 seconds. If the
problem persists, remove the water supply line and check the water supply. The water supply line ow rate should be
at least 8 liters per minute to ensure an adequate ush.
12.3.3 SHOWER
To protect the surface of your ABS plastic shower pan, it is recommended that a rubber shower mat be placed in the shower
pan.
Use a non-abrasive cleaner to clean your shower compartment. Do not use highly concentrated or high acid content house-
hold cleaners, as these may damage the shower compartment.
12.4 PLUMBING SPECIFICATIONS
12.4.1 TANK CAPACITIES
See spec sheet. Capacities may vary per oorplan.