EasyManua.ls Logo

TVC Ethos Two - Page 31

Default Icon
102 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 31 of 102
TVL 351
ISSUE 15
Code-076 CONTROL SGL **Brown Out Reset***.
Brown Out Reset, The internal CPU has reset due to a brown out on it's power supply.
[Fault]
Code-077 CONTROL SGL ***External Reset***.
Reset push has been pressed, The internal CPU has detected the NRST signal go low.
[Fault]
Code-078 CONTROL SGL ***Power on Reset***.
Power on reset, The mains supply has been removed from more than 1 second, check supply wiring or fuses, riser
supply.
[Information]
Code-079 CONTROL SGL **Low Power Reset***.
Low power reset, The internal CPU has had a low power reset.
[Fault]
Code-080 MOTION SGL Emergency Slowdown.
Emergency slowdown. The lift was over speeding as it came into the terminal floor or had a fault that required
immediate slowdown, check BFR/TFR/DZ switches, encoders and slowing points / setup.
[Fault]
Code-081 DRIVE SGL MC Lost On Start.
MC feedback lost on starting, check safety circuit/terminal limits, motor overload contacts and drive start settings.
[Fault]
Code-082 DRIVE SGL MC Lost On Stop.
MC feedback lost on stopping sequence, check brake set timing, drive stopping sequence and safety circuit/terminal
limits.
[Fault]
Code-083 MOTION MAN Multi Head Error / Multi Head Reset.
Leveller error on 3 accumulated journeys, check tape head signals (LU/LD/DZ,DZM). Clear fault in toolbox menu.
[Breakdown]
Code-084 MOTION SGL Fail To Leave Floor.
Lift has failed to leave floor, check drive if stalled. Status of LU/LD has not changed after set time. Three of these
events will give a Multi Start Fail code 014. The Factory defaults for the Escape Floor Time are 2.1 seconds for lifts
running at 1m/s or greater, otherwise it is set at 4.2 seconds.
[Fault]
Code-085 MOTION SGL Start Leveller Or Direction Error.
Leveller or direction error on start, check signals (LU/LD), check brake settings for rollback and associated start
timers.
[Fault]
Code-086 CONTROL SGL RTC Time Set.
The real time clock time has been set to a new value by the User.
[Information]
Code-087 CONTROL SGL RTC Date Set.
The real time clock date has been set to a new value by the User.
[Information]
Code-088 MOTION SGL Lift Is LOST.
lift is lost due to position data being not valid, check shaft positioning equipment, shaft encoder settings. Lift will dive
on next journey
[Fault]
Code-089 MOTION SGL Re-Level Timeout.
Lift failed to re-level after 5 seconds, check levellers (LU/LD) and drive settings.
[Fault]

Table of Contents

Other manuals for TVC Ethos Two